抄録
In this article, transmission time in multi hop networks is discussed. In general, transmission times caused by a router vary according to the router's load and traffic of networks. So when two nodes communicate with each other via some routers, real-time property never be ensured even if these nodes are a part of subnet organized by conventional factory communication systems. To stabilize the transmission time, this article propose to revise factory communication protocols so as to synchronize the assignment of time-slots for a periodical communication for each side segments of routers. Very simple example of synchronized time-slot assignment method is also shown.
本文言語 | English |
---|---|
ページ | 2903-2908 |
ページ数 | 6 |
DOI | |
出版ステータス | Published - 2002 |
イベント | Proceedings of the 2002 28th Annual Conference of the IEEE Industrial Electronics Society - Sevilla, Spain 継続期間: 2002 11月 5 → 2002 11月 8 |
Other
Other | Proceedings of the 2002 28th Annual Conference of the IEEE Industrial Electronics Society |
---|---|
国/地域 | Spain |
City | Sevilla |
Period | 02/11/5 → 02/11/8 |
ASJC Scopus subject areas
- 制御およびシステム工学
- 電子工学および電気工学