TY - JOUR
T1 - Temperature-responsive mixed-mode column for the modulation of multiple interactions
AU - Nagase, Kenichi
AU - Matsumoto, Kosuke
AU - Kanazawa, Hideko
N1 - Funding Information:
Part of this work was supported by Grants-in-Aid for Scientific Research (Grant nos. 19H02447 and 20H05233) from the Japan Society for the Promotion of Science (JSPS), Japan, and a SENTAN grant (Grant no. JPMJSN16B3) from the Japan Science and Technology Agency (JST), Japan.
Publisher Copyright:
© 2022, The Author(s).
PY - 2022/12
Y1 - 2022/12
N2 - In this study, mixed-mode chromatography columns have been investigated using multiple analyte interactions. A mixed-mode chromatography column was developed using poly(N-isopropylacrylamide) (PNIPAAm) brush-modified silica beads and poly(3-acrylamidopropyl trimethylammonium chloride) (PAPTAC) brush-modified silica beads. PNIPAAm brush-modified silica beads and PAPTAC brush-modified silica beads were prepared by atom transfer radical polymerization. The beads were then packed into a stainless-steel column in arbitrary compositions. The elution studies evaluated the column performance on hydrophobic, electrostatic, and therapeutic drug samples using steroids, adenosine nucleotide, and antiepileptic drugs as analytes, respectively. Steroids exhibited an increased retention time when the column temperature was increased. The retention of adenosine nucleotides increased with the increasing composition of the PAPTAC-modified beads in the column. The antiepileptic drugs were separated using the prepared mixed-mode columns. An effective separation of antiepileptic drugs was observed on a 10:1 PNIPAAm:PAPTAC column because the balance between the hydrophobic and electrostatic interactions with antiepileptic drugs was optimized for the bead composition. Oligonucleotides were also separated using mixed-mode columns through multiple hydrophobic and electrostatic interactions. These results demonstrate that the developed mixed-mode column can modulate multiple hydrophobic and electrostatic interactions by changing the column temperature and composition of the packed PNIPAAm and PAPTAC beads.
AB - In this study, mixed-mode chromatography columns have been investigated using multiple analyte interactions. A mixed-mode chromatography column was developed using poly(N-isopropylacrylamide) (PNIPAAm) brush-modified silica beads and poly(3-acrylamidopropyl trimethylammonium chloride) (PAPTAC) brush-modified silica beads. PNIPAAm brush-modified silica beads and PAPTAC brush-modified silica beads were prepared by atom transfer radical polymerization. The beads were then packed into a stainless-steel column in arbitrary compositions. The elution studies evaluated the column performance on hydrophobic, electrostatic, and therapeutic drug samples using steroids, adenosine nucleotide, and antiepileptic drugs as analytes, respectively. Steroids exhibited an increased retention time when the column temperature was increased. The retention of adenosine nucleotides increased with the increasing composition of the PAPTAC-modified beads in the column. The antiepileptic drugs were separated using the prepared mixed-mode columns. An effective separation of antiepileptic drugs was observed on a 10:1 PNIPAAm:PAPTAC column because the balance between the hydrophobic and electrostatic interactions with antiepileptic drugs was optimized for the bead composition. Oligonucleotides were also separated using mixed-mode columns through multiple hydrophobic and electrostatic interactions. These results demonstrate that the developed mixed-mode column can modulate multiple hydrophobic and electrostatic interactions by changing the column temperature and composition of the packed PNIPAAm and PAPTAC beads.
UR - http://www.scopus.com/inward/record.url?scp=85126540663&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85126540663&partnerID=8YFLogxK
U2 - 10.1038/s41598-022-08475-8
DO - 10.1038/s41598-022-08475-8
M3 - Article
C2 - 35292748
AN - SCOPUS:85126540663
SN - 2045-2322
VL - 12
JO - Scientific reports
JF - Scientific reports
IS - 1
M1 - 4434
ER -