TY - JOUR
T1 - Total aortic arch replacement using the J-graft open stent graft for distal aortic arch aneurysm
T2 - Report from two centres in Japan
AU - Tsutsumi, Koji
AU - Ishida, Osamu
AU - Yamanaka, Nozomu
AU - Hayashi, Kanako
AU - Hashizume, Kenichi
N1 - Publisher Copyright:
© 2021 The Author(s). Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
PY - 2021/10/1
Y1 - 2021/10/1
N2 - OBJECTIVES: The open-style stent graft technique has been changing the strategy for true distal arch aneurysms extending to the descending aorta. Our mid-term results of surgical repair using a J-graft open stent graft are presented. METHODS: Between May 2015 and June 2020, 69 patients with a distal arch aneurysm (53 males, median age 74 years) underwent total arch replacement combined with J-graft open stent deployment. All 59 surviving patients were followed for a median follow-up period of 1.8 (0.6-3.6) years. RESULTS: Antegrade deployment was successfully performed in all patients without any difficulties. The deployed device was securely fixed at the target area, and it initiated thrombus formation. The diameter of the excluded aneurysm was decreased in 54 patients (91.5%) during the follow-up period. There were no type I endoleaks, but there were 3 type II endoleaks; 2 of the 3 type II endoleaks disappeared during the follow-up period. Additional endovascular operations were performed in 3 patients. There were 10 in-hospital deaths (14.5%), and the incidences of stroke, spinal cord injury and distal embolism were 11.6%, 5.8% and 2.9%, respectively. The 1-and 3-year survival rates were 84.8% and 79.4%, respectively, and the 1-and 3-year freedom from reintervention rates were 97.2% and 81.3%, respectively. CONCLUSIONS: The J-graft open stent graft was easy to deploy, and it could shift the distal anastomosis to a more proximal side. The mid-term performance of this device was good. It has the potential to provide one-stage repair.
AB - OBJECTIVES: The open-style stent graft technique has been changing the strategy for true distal arch aneurysms extending to the descending aorta. Our mid-term results of surgical repair using a J-graft open stent graft are presented. METHODS: Between May 2015 and June 2020, 69 patients with a distal arch aneurysm (53 males, median age 74 years) underwent total arch replacement combined with J-graft open stent deployment. All 59 surviving patients were followed for a median follow-up period of 1.8 (0.6-3.6) years. RESULTS: Antegrade deployment was successfully performed in all patients without any difficulties. The deployed device was securely fixed at the target area, and it initiated thrombus formation. The diameter of the excluded aneurysm was decreased in 54 patients (91.5%) during the follow-up period. There were no type I endoleaks, but there were 3 type II endoleaks; 2 of the 3 type II endoleaks disappeared during the follow-up period. Additional endovascular operations were performed in 3 patients. There were 10 in-hospital deaths (14.5%), and the incidences of stroke, spinal cord injury and distal embolism were 11.6%, 5.8% and 2.9%, respectively. The 1-and 3-year survival rates were 84.8% and 79.4%, respectively, and the 1-and 3-year freedom from reintervention rates were 97.2% and 81.3%, respectively. CONCLUSIONS: The J-graft open stent graft was easy to deploy, and it could shift the distal anastomosis to a more proximal side. The mid-term performance of this device was good. It has the potential to provide one-stage repair.
KW - Open stent graft
KW - Total arch replacement
KW - True distal arch aneurysm
UR - https://www.scopus.com/pages/publications/85117515109
UR - https://www.scopus.com/pages/publications/85117515109#tab=citedBy
U2 - 10.1093/icvts/ivab114
DO - 10.1093/icvts/ivab114
M3 - Article
C2 - 34329416
AN - SCOPUS:85117515109
SN - 1569-9293
VL - 33
SP - 614
EP - 621
JO - Interactive Cardiovascular and Thoracic Surgery
JF - Interactive Cardiovascular and Thoracic Surgery
IS - 4
ER -