TY - GEN
T1 - Tumor detection method of small animals on X-ray images
AU - Karita, Yuji
AU - Tanaka, Toshiyuki
AU - Kabaya, Isao
AU - Kano, Mikiya
AU - Iwayoshi, Isamu
PY - 2007
Y1 - 2007
N2 - Tumor diagnosis by X-ray images is a standard way in small animals. But it is difficult to decide tumor region of X-ray images, and veterinarians have to diagnose many X-ray images. Therefore, there is increasing demand for the development of CAD (Computer Aided Diagnosis) system to support veterinarians. We use X-ray images of small animals such as dogs. In this paper, automatic detection of tumor region from X-ray images is studied. We use normalized correlation between original image and template image to emphasize tumor region. This template image is based on feature of tumor. We also use Quoit filter to detect tumor candidate regions. Then, we calculate two feature values, mean of intensity and roundness in these regions, and classify these two feature values into four patterns by K-means clustering to decide true tumor region. As a result, some tumor region can be detected.
AB - Tumor diagnosis by X-ray images is a standard way in small animals. But it is difficult to decide tumor region of X-ray images, and veterinarians have to diagnose many X-ray images. Therefore, there is increasing demand for the development of CAD (Computer Aided Diagnosis) system to support veterinarians. We use X-ray images of small animals such as dogs. In this paper, automatic detection of tumor region from X-ray images is studied. We use normalized correlation between original image and template image to emphasize tumor region. This template image is based on feature of tumor. We also use Quoit filter to detect tumor candidate regions. Then, we calculate two feature values, mean of intensity and roundness in these regions, and classify these two feature values into four patterns by K-means clustering to decide true tumor region. As a result, some tumor region can be detected.
KW - Clustering
KW - Correlation
KW - Filter
KW - Small animals
KW - X-ray images
UR - http://www.scopus.com/inward/record.url?scp=50349092420&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=50349092420&partnerID=8YFLogxK
U2 - 10.1109/SICE.2007.4421072
DO - 10.1109/SICE.2007.4421072
M3 - Conference contribution
AN - SCOPUS:50349092420
SN - 4907764286
SN - 9784907764289
T3 - Proceedings of the SICE Annual Conference
SP - 698
EP - 702
BT - SICE Annual Conference, SICE 2007
T2 - SICE(Society of Instrument and Control Engineers)Annual Conference, SICE 2007
Y2 - 17 September 2007 through 20 September 2007
ER -