TY - JOUR
T1 - Two cases of digitalis toxicity with reversible and severe decrease of visual acuity
AU - Nagai, Norihiro
PY - 2001/12/1
Y1 - 2001/12/1
N2 - Background : We performed electrophysiologic tests on two patients with digitalis toxicity who first had photophobia and xanthopsia and revealed reversible reduced visual acuity and binocular central scotoma. Cases: The patients were a 72-year-old male and a 54-year-old male who had symptoms of digitalis toxicity. Findings: The corrected visual acuity was severely decreased during digitalis toxicity, 0.02 oculus dexter (OD) and 0.1 oculus sinister (OS) in case 1 and 0.04 OD and 0.2 OS in case 2. But visual acuity recovered as the blood levels of digitalis decreased to the normal level and the corrected visual acuity was 0.7 OD and 0.8 OS in case 1 and 0.8 OD and 0.9 OS in case 2. We recorded 30 Hz-flicker electroretinogram (ERG), single flash ERG, photopic ERG, and scotopic ERG when digitalis blood levels were elevated and normal. Decreased amplitudes of 30 Hz-flicker ERG and photopic ERG suggested that photoreceptor function was disturbed at digitalis toxicity and cone dysfunction was more severely disturbed than rod dysfunction. Conclusion : 30 Hz-flicker ERG, as well as electrocardiogram and digitalis blood level, is a relatively convenient and useful measure of digitalis toxicity. It is necessary consiler toxicity when severe visual dysfunction is observed in patients with digitalis therapy.
AB - Background : We performed electrophysiologic tests on two patients with digitalis toxicity who first had photophobia and xanthopsia and revealed reversible reduced visual acuity and binocular central scotoma. Cases: The patients were a 72-year-old male and a 54-year-old male who had symptoms of digitalis toxicity. Findings: The corrected visual acuity was severely decreased during digitalis toxicity, 0.02 oculus dexter (OD) and 0.1 oculus sinister (OS) in case 1 and 0.04 OD and 0.2 OS in case 2. But visual acuity recovered as the blood levels of digitalis decreased to the normal level and the corrected visual acuity was 0.7 OD and 0.8 OS in case 1 and 0.8 OD and 0.9 OS in case 2. We recorded 30 Hz-flicker electroretinogram (ERG), single flash ERG, photopic ERG, and scotopic ERG when digitalis blood levels were elevated and normal. Decreased amplitudes of 30 Hz-flicker ERG and photopic ERG suggested that photoreceptor function was disturbed at digitalis toxicity and cone dysfunction was more severely disturbed than rod dysfunction. Conclusion : 30 Hz-flicker ERG, as well as electrocardiogram and digitalis blood level, is a relatively convenient and useful measure of digitalis toxicity. It is necessary consiler toxicity when severe visual dysfunction is observed in patients with digitalis therapy.
KW - 30 hz-flicker ERG
KW - Decreased visual accuity
KW - Digitalis
KW - Digitalis toxicity
UR - http://www.scopus.com/inward/record.url?scp=0035228884&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0035228884&partnerID=8YFLogxK
M3 - Article
C2 - 11210783
AN - SCOPUS:0035228884
SN - 0029-0203
VL - 105
SP - 24
EP - 30
JO - Journal of Japanese Ophthalmological Society
JF - Journal of Japanese Ophthalmological Society
IS - 1
ER -